Work

Parameter optimization of femtosecond laser pulses for implant cavity preparation

Year: 2024
Type: article
Abstract: Femtosecond laser pulses are employed in the preparation of implant cavities during dental implant surgeries in the field of digital dentistry, specifically focusing on optimizing laser pulse parameters to enhance precision and control thermal injury. In this study, ex vivo experiments were conducted on sheep tibiae, where thermocouple sensors monitored the temperature variations during ablation. This approach aims to optimize the laser pulse parameters and control the temperature, ensuring smoother cavity margins and better preservation of the bone microarchitecture. Scanning electron microscopy (SEM) confirmed significant improvements in the quality of the implant cavities prepared using the femtosecond laser pulses.
Authors: Wanqiang Chen, Fusong Yuan, Shanshan Liang, Chen Qu, Shuting Lin, Xiang Li, Lei Yan, Xuesong Shi, Wei Yi
Language: English
Field: Medicine
Open Access status: gold
Estimated APC paid: $1,913
OpenAlex ID: W4405784444
FWCI: 0.229
Cites: 37
Cited by: 1
Related to: 10