Year: 2024
Type: article
Study design: Case Report
Abstract: Background The management of type 1 diabetes in pregnancy with new technologies is challenging. Sometimes the complexity of new-generation systems such as CSII (continuous subcutaneous insulin infusion) and patient or provider preference do not allow their use, so women with type 1 diabetes in pregnancy continue to be treated with subcutaneous multiple injection insulin therapy using pens. Smart insulin pens are new tools that allow data collection on insulin dose and time of administration and have additional connectivity features. Objective To retrospectively describe the use of a smart insulin pen coupled with rt-CGM (InPen TM system) in 3 pregnancies complicated by type 1 diabetes. The cases presented are the first report of the use of the smart insulin pen in type 1 diabetic patients during pregnancy.
Source: Healthcare
Language: English
Subfield: Endocrinology, Diabetes and Metabolism
Field: Medicine
Domain: Health Sciences
Open Access status: gold
Estimated APC paid: $3,069
OpenAlex ID: W4405934119