Work

Physics-Informed Autoencoder for DSC-MRI Perfusion Post-Processing: Application to Glioma Grading

Year: 2025
Type: conference-paper
Abstract: DSC-MRI perfusion is a medical imaging technique for diagnosing and prognosing brain tumors and strokes. Its analysis relies on mathematical deconvolution, but noise or motion artifacts in a clinical environment can disrupt this process, leading to incorrect estimates of perfusion parameters. Although deep learning approaches have shown promising results, their calibrations typically rely on third-party deconvolution algorithms to generate reference outputs and are bound to reproduce their limitations. To address this problem, we propose a physics-informed autoencoder that uses an analytical model to decode the perfusion parameters and guide the learning of the encoding network. This autoencoder is trained in a self-supervised fashion without any third-party software and its performance is evaluated on a database with glioma patients. Our method shows reliable results for glioma grading in accordance with other well-known deconvolution algorithms despite a lower computation time. It also achieved competitive performance even in the presence of high noise, which is critical in a medical environment.
Language: English
Field: Medicine
Open Access status: green
Award: G57424851
OpenAlex ID: W4406205869
FWCI: 3.035
Cites: 13
Cited by: 1