Aortic rupture during transcatheter aortic valve replacement requiring emergent thoracic endovascular aortic repair and endograft infection requiring endograft explant
Year: 2025
Type: article
Study design: Case Report
Abstract: Infection of endografts after thoracic endovascular aortic repair (TEVAR) is a catastrophic complication with dramatically high morbidity and mortality. We present the case of a 58-year-old gentleman who underwent TEVAR for aortic rupture during transcatheter aortic valve replacement, later presenting with TEVAR infection, endocarditis, and aortobronchial fistula who underwent TEVAR explantation, aortic valve replacement, and aortic reconstruction. The patient consented to publication of his operative course.
Institution: Washington University in St. Louis
Language: English
Subfield: Surgery
Field: Medicine
Domain: Health Sciences
Open Access status: gold
Estimated APC paid: $1,250
OpenAlex ID: W4407122042