Year: 2025
Type: article
Abstract: Grid-connected single-phase inverters require accurate phase detection for synchronization and power control. Traditionally, phase-locked loops (PLLs) are used to estimate grid parameters. This paper proposes a novel approach that determines the grid phase angle using only current feedback, eliminating the need for grid voltage measurements or cascaded control schemes. The proposed method integrates a phase angle observer with a current controller to regulate real and reactive power. Lyapunov stability analysis and hardware experiments validate the effectiveness of the approach.
Source: Energies
DOI: 10.3390/en18040941
Authors: Shruti Pandey, Michael Mclntyre
Institution: University of Louisville
Language: English
Subfield: Control and Systems Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: gold
Estimated APC paid: $3,137
OpenAlex ID: W4407670267