Work

Economic Impact of Energy Accounting Schemes for Commercial Systems on a Broiler Farm with Power Demand and Generation

Year: 2025
Type: article
Abstract: The aim of this study was to assess the impact of the on-farm solar photovoltaic (PV) generation to offset grid electricity consumption on a commercial poultry farm in the US. Hourly electricity production by PV systems was estimated using the System Advisor Model (SAM) of the National Renewable Energy Lab (NREL) and compared with the estimated electric load demand of a broiler house. We analyzed the economic benefits of installing solar systems of three capacities under net energy metering and net energy billing pricing scenarios. Results suggested that a smaller PV installation of 35 kWp, while substantially short of meeting energy needs, resulted in an 85% self-consumption ratio, whereas the larger 70 kWp and 105 kWp PV systems, led to 59% and 42% self-consumption ratios, respectively. This is important when analyzing pricing schemes as lesser amounts of PV energy created are sold to the grid with the smallest system, and, thereby, the least pricing effects on profitability occur across pricing scenarios. Although all scenarios lead to positive net present values (NPVs), under either type of the pricing scenarios, farm business owners realize more favorable energy sales with NEM, which would spur PV system adoption. Results of this study thus provide information to both poultry farmers, considering the size of system installations and policy makers interested in affordably increasing renewable energy supplies and/or rural development.
Source: Energies
Language: English
Open Access status: gold
Estimated APC paid: $3,137
OpenAlex ID: W4407720007
FWCI: 0.571
Cites: 9
Cited by: 2
Related to: 10