Research and analysis of AP1000 nuclear fan belt fracture fault
Year: 2025
Type: conference-paper
Abstract: Belt breakage faults often occur in the supply fan of the radioactive waste building in the nuclear power plant. To avoid affecting the normal operation of the fan, the regular replacement frequency of the fan belt was shortened, but the breakage still occurred. Through testing and analysis of belts produced by different manufacturers, a detailed and in-depth analysis was conducted from different perspectives, and corresponding conclusions were drawn. At the same time, follow-up action suggestions were also provided, providing a good reference for improving the operational reliability of similar fans.
Authors: Shuaishuai Li, Yang Wang, Tianzuo Qu, Ruiheng Ou, Dalin Wang, Weiyan Meng
Language: English
Subfield: Mechanical Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: diamond
OpenAlex ID: W4407768903