Work

Assessment of the pollutant dispersion, linear system and stability through the application of the 3D-GILTT method in the advection-diffusion equation

Year: 2024
Type: article
Abstract: The aim of this work is to evaluate the pollutants concentration considering a transient three-dimensional model, non-local turbulence closure and the computational time to simulate the pollutants dispersion considering different methodologies to solve the linear system that is obtained by applying the 3D-GILTT method in the three-dimensional advection-diffusion equation. To validate the model, unstable tank experiment data were considered. The results show that the Gauss-Seidel method has the shortest computational time to simulate the pollutant dispersion and the model satisfactorily simulates the observed concentrations, considering and not considering the non-local turbulence closure term.
Language: English
Open Access status: diamond
OpenAlex ID: W4408046973
FWCI:
Cites: 11
Cited by:
Related to: 10