Percutaneous device closure for Paravalvular leak- A single centre experience
Year: 2025
Type: article
Abstract: The incidence of paravalvular leak (PVL) following surgical valve replacement is 5-17%. Our main aim is to determine the safety and efficacy of percutaneous device closure for significant PVLs.Transcatheter device closure was done for 45 PVLs in 42 patients. PVLs were closed percutaneously in mitral position in 23 cases, in aortic position in 20 cases, and combined mitral and aortic leaks in 2 cases. We achieved a technical success rate of 93.33 % and procedural success rate of 91.11%. Transcatheter PVL closure is a safe and effective procedure for symptomatic PVLs.
Source: Indian Heart Journal
Institution: Narayana Health
Language: English
Subfield: Cardiology and Cardiovascular Medicine
Field: Medicine
Domain: Health Sciences
Open Access status: gold
Estimated APC paid: $360
OpenAlex ID: W4408185854