Evaluating the Educational Effectiveness of Surface Radioactive Contamination Survey Techniques
Year: 2025
Type: article
Study design: Clinical Trial
Abstract: In this study, we evaluated the educational effectiveness of training by reviewing recorded data on contamination survey techniques and real-time display feedback. An optical flow (OF) sensor and a distance sensor were used to measure the speed and distance, respectively. The sensors were mounted on a radiation measuring device, and the contamination survey techniques of the 12 participants were recorded. The recorded data and real-time technique feedback was used to conduct training, after which the participants performed contamination surveys once more. Speed and distance both significantly decreased after training, with speed dropping from 4.70 to 3.45 cm s −1 and distance decreasing from 1.16 to 0.90 cm. Additionally, variations during surveys showed a significant reduction.
Source: Radioprotection
Authors: S. Hosokawa, A. Nakamura, H. Ose, M. Osanai, R. Mori, K. Okuda, T. Tsujiguchi, T. Tomisawa, Y. Takahashi
Institution: Hirosaki University
Language: English
Subfield: Safety, Risk, Reliability and Quality
Field: Engineering
Domain: Physical Sciences
SDG: Quality education
Open Access status: hybrid
Estimated APC paid:
OpenAlex ID: W4408322918