Levitation of posteriorly dislocated intraocular lens: I.V. catheter connected to the vitreotome aspiration
Year: 2025
Type: article
Abstract: Background: To introduce a new, simple, and affordable technique that uses a 22G intravenous (I.V.) catheter connected to the vitreotome aspiration to lift the intraocular lens (IOLs) off the retina. Methods: This retrospective, non-comparative, single surgeon, interventional, consecutive case series examined 4 patients (4 eyes) who underwent the surgical procedure from March 12 and October 22, 2023. Reliability, reproducibility, and intraoperative and postoperative complications of the technique were analyzed. Results: Four patients presenting with posteriorly dislocated IOLs were included. After a complete 23G vitrectomy under wide-angle viewing system or high magnification contact lens, the 22G I.V. catheter was connected to the vitreotome aspiration and active aspiration was applied. When the IOLs were lifted towards the posterior chamber by continuous vacuum aspiration, they were be safely grasped using intraocular forceps and reposited with scleral fixation suturing or removed through a limbal incision. None of the IOLs fell during active aspiration. Conclusion: Connection of I.V. catheter with vitreotome aspiration to lift the IOLs off the retina was a new, simple, safe, and affordable technique.
Source: Frontiers in Ophthalmology
Authors: Ruiping Gu, Yue Guo, Yuan Zong, Rui Jiang, Zhongcui Sun
Language: English
Subfield: Ophthalmology
Field: Medicine
Domain: Health Sciences
Open Access status: gold
Estimated APC paid: $2,353
OpenAlex ID: W4408417665