Abstract: Prior to moving newly developed catalyst-coated membranes (CCMs) into large applications for proton exchange membrane water electrolyzers (PEMWEs), a scaling-up test is essential. However, this usually experiences a large performance drop due to the design challenges faced in the testing cell and assembly with a large active area. This work investigates a series of parameters in assembling the testing cell when scaling up the CCM from 5 cm 2 to 50 cm 2 , including assembling force, gasket thickness, and their combination with different porous transport layers (PTLs). At an optimal assembling construction, a CCM with an active area of 5 cm 2 achieves a current density of 2.4 A/cm 2 at 1.8 V when tested in a 50 cm 2 testing cell. In comparison, the same CCM achieves 2.2 A/cm 2 when tested in a 5 cm 2 testing cell. However, when scaling up to a CCM with an active area of 50 cm 2 , the current density drops to 1.73 A/cm 2 . The influence mechanisms are then explored with the assembly procedures for further improvement of the testing performance of PEM water electrolyzers.