Work

Unstented large fenestration for close target vessel ostia: Long-term follow-up

Year: 2025
Type: article
Study design: Case Report
Abstract: PurposeTo report the 10-year follow-up of a patient managed with a custom-made fenestrated endograft, including a large fenestration for the preservation of a celiac trunk (CT) anatomic variation.Case reportIn 2014, a 75-year-old female was treated endovascularly for descending thoracic and visceral aortic pseudoaneurysms (PA). Due to a celiac trunk (CT) anatomic variation, consisting of separate origins of the hepatic and splenic artery, a custom-made four-fenestrated endograft was planned, including a large fenestration (18 × 10 mm) for CT preservation. Balloon-expandable covered stents bridged all target vessels (TVs), except the large fenestration, which was left unstented. Imaging at 10 years showed patency of TVs, no signs of instability or device migration and complete PA exclusion.ConclusionUsing a patient-specific device for complex endovascular aortic repair provided favorable extended follow-up outcomes. An unstented large fenestration remained patent during 10 years of follow-up. This case highlights the importance of individualized approach in complex aortic pathologies.
Source: Vascular
Language: English
Field: Medicine
Open Access status: hybrid
Estimated APC paid: $4,150
OpenAlex ID: W4408634502
FWCI:
Cites: 10
Cited by:
Related to: 10