Work

Proposal of Seismic Retrofit Method by Adhesively Bonding for Steel Pipe Members and Evaluation Method of Joint Capacity

Year: 2025
Type: article
Abstract: For seismic retrofit steel frame buildings, on-site welding and drilling for bolted joint often can not be applied because of fire safety concerns, overly thin plate and section loss. The authors have proposed a welding-free joint method for existing steel pipe members consisting of adhesive and non-adhesive bonding connections.
Language: English
Open Access status: bronze
OpenAlex ID: W4409013334
FWCI:
Cites: 1
Cited by:
Related to: 10