Work

STATISTICAL ANALYSIS OF IN-SERVICE ULTRASONIC INSPECTION DATA OF WASTE TANKS AT THE SAVANNAH RIVER Site-25021

Year: 2025
Type: conference-paper
Abstract: CONCLUSIONS AND RECOMMENDATIONS •“There is no evidence of pit depth growth over the last 15-years demonstrating the effectiveness of the corrosion control program. •“Incipient pits” are not growing and are likely pre-service pits. • No need to continue measuring these tiny pits. However, due to the random nature of pit initiation and the potentially accelerated growth of a pit, periodic monitoring for pit growth is prudent. 1. No reportable pits were identified. All identified pits are far less than the reportable depth of 25% of the nominal wall thickness. 2. No cracking was identified. 3. There is no evidence that active, systemic corrosion has occurred in Tank 29 during its 38-year service history as of 2009.
Language: English
Open Access status: green
OpenAlex ID: W4409151148
FWCI:
Cites:
Cited by:
Related to: 10