Enhancing management of double outlet right ventricle when the interventricular communication is remote from the arterial roots through three-dimensional printing
Year: 2025
Type: article
Study design: Case Report
Abstract: BACKGROUND: Double outlet right ventricle with remote interventricular communication presents significant surgical challenges. Traditional imaging often fails to provide the detailed, three-dimensional anatomical insights required for complex cases. Advancements in three-dimensional (3D) printing offer a valuable tool for preoperative planning and decision-making. CASES: In the first case, a 5-year-old with double outlet right ventricle and remote interventricular communication underwent a Glenn procedure with anticipated univentricular repair. 3D printing revealed the potential for enlarging the communication, leading to a one-and-a-half ventricle repair. The second case involved a 2-day-old infant with double outlet right ventricle, aortic arch interruption, and remote communication. At one year, 3D modelling enabled a successful left ventricle-to-aorta baffle. CONCLUSION: These cases underscore 3D printing's role in improving precision, reducing complications, and potentially lowering costs in managing complex congenital heart disease.
Source: 3D Printing in Medicine
Language: English
Subfield: Epidemiology
Field: Medicine
Domain: Health Sciences
Open Access status: gold
Estimated APC paid: $2,190
OpenAlex ID: W4409210436