Year: 2025
Type: article
Abstract: Transmission of stable ripple-free power to heating regions is necessary to maintain temperature stability.Ripples in the power supply would result in high power losses together with unpredictable and abnormal temperature rises and power state instability.Excessive current ripple causes electrolytic capacitors in the circuit to decrease their operational life span.This article presents a plan that reduces load management ripple factor to 0.4% by using simple cost-effective available electronic components.
Author: Wang Chie C
Institution: Tsinghua University
Language: English
Topic: Advanced DC-DC Converters
Subfield: Electrical and Electronic Engineering
Field: Engineering