Year: 2025
Type: article
Abstract: The article considers the basic mechanism and the construction details of lithium-ion batteries causing their fire and explosion hazard. It gives the results of fire-technical examinations carried out by RFCFS which confirm the possibility of fires due to the emergency operation mode of lithium-ion batteries. It is shown that use of an instrumental method for detection of the emergency operation traces left after fire on the battery fragments is not a sufficient reason to conclude that this operation mode caused the fire.
Language: English
Subfield: Automotive Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: diamond
OpenAlex ID: W4409564082