Real-time Detection of Foodborne Pathogens and Biofilm in the Food Processing Environment with Bactiscan, A Macro-scale Fluorescence Device
Year: 2025
Type: article
Abstract: CFU by ATP swab testing, where Bactiscan detection limits were defined by the concentration at which 50% of the samples were observed under illumination of the device. Heat-killed and chlorine-stressed E. coli and S. enterica caused a 2-log reduction in detection by ATP swab tests (p ≤ 0.05), while detection by Bactiscan was unaffected (p ≥ 0.05). Pathogen biofilms were detectable via Bactiscan with >80% accuracy at 4 days of growth; E. coli and L. monocytogenes biofilms were visible at 2 days of growth. In situ contamination studies determined that Bactiscan can detect microbial contamination on chicken, salmon, and yoghurt samples with stronger fluorescence than a competitor's UV torch. The presence of one of the pathogens on the food samples was confirmed by metagenome sequencing, determining that S. aureus was present in 7 samples out of 9 with a relative abundance of >0.5%. These data demonstrate that Bactiscan can effectively detect bacteria present in the food processing environment and can complement existing technologies to improve food industry cleaning practices and infection prevention.
Source: Journal of Food Protection
Authors: Callum Highmore, Kirsty Cooper, Joe Parker, Joshua Robinson, Roberto Castangia, Jeremy S. Webb
Institution: University of Southampton
Language: English
Topic: Food Safety and Hygiene
Subfield: Food Science
Domain: Life Sciences
Open Access status: gold
Estimated APC paid: $2,300
Awards: G2205001515, G5271628241
OpenAlex ID: W4409638360