Year: 2025
Type: article
Abstract: Ultrasonic tests are widely used, both in laboratory and industrial settings, to assess the quality of joints, mainly welded joints. Studies are being carried out on the possibility of ultrasonic evaluation of adhesive joints. This study was conducted using signal analysis in the time and frequency domains. The ultrasonic probes used in the tests were selected on the basis of the properties of the test elements. For example, when testing welded joints, ultrasonic probes with a water delay line bounded by a thin diaphragm were used. Since adhesives have different acoustic properties, it is necessary to evaluate the capabilities of different ultrasonic probes to test adhesive joints. Tests were conducted for two different adhesives (cyanoacrylate and structural) and eight ultrasonic probes with a frequency range of 1.660 to 13.70 MHz. In the literature, no studies have analyzed the use of ultrasonic probes at such different frequencies. Frequency has the greatest effect on the attenuation of ultrasonic waves and the ultrasonic wavelength, and it was noted that the adhesive could cause a 25 percent change in the maximum frequency of the ultrasonic pulse. It was also found that it is necessary to make reference samples before ultrasonic testing of adhesive joints, since specific frequencies can produce erroneous signals for the selected adhesives.
Source: Materials
DOI: 10.3390/ma18091946
Author: Jakub Kowalczyk
Institution: Poznań University of Technology
Language: English
Subfield: Mechanics of Materials
Field: Engineering
Domain: Physical Sciences
Open Access status: gold
Estimated APC paid: $3,137