Pengaruh Kuat Arus Listrik Pada Pengelasan Metal Inert Gas (mig) Terhadap Sambungan Logam Aluminium
Year: 2024
Type: article
Abstract: The aim of this research is to calculate and compare the tensile strength of MIG welding with different current variations, apart from that it can also obtain optimal electric current variations in MIG (Metal Inert Gas) welding, electric current variations namely 150 amperes, 155 amperes and 160 amperes. Data from tensile test results using ASTM B 557M 02-a standard with the highest tensile stress value obtained in welding using a current of 155 amperes, namely 13.03 kg/mm² and the lowest tensile stress value at a current of 160 amperes 9.47 kg/ mm².
Source: JNSTA ADPERTISI JOURNAL
Authors: Muhammad Alwi Laumma, Kartini Yunus
Language: English
Subfield: Mechanical Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: bronze
OpenAlex ID: W4409837086