LC biosensors (Bio-LC): new resonant sensors for direct detection of airborne viruses
Year: 2025
Type: article
Abstract: Viruses suspended in the air are key in the transmission of infectious diseases. We present a label-free selective system capable of detecting in situ airborne viruses in ambient air, employing resonant LC (Inductor-Capacitator) circuits. As proof of principle, M13 bacteriophages were nebulized and monitored with this sensor. The selective recognition of viruses by the copper immune-functionalized inductor of an LC circuit resulted in shifts of its resonant frequency proportional to the virus ambient concentration. The selectivity of this resonator is due to the employed bioreceptor. So, the lowest ambient concentration of airborne M13 bacteriophage that can be selectively detected is 3 × 10 5 pfu L −1 . This biosensing approach opens appealing perspectives for controlling the transmission of infectious diseases. • Detecting airborne viruses in real-time using a label-free system. • Selective recognition of viruses through immune-functionalized LC circuits. • First demonstration of in situ detection of viruses in ambient air. • Portable platform offers a low detection limit of 3 × 10 5 pfu L −1 . • A breakthrough biosensing approach for controlling infectious disease transmission.
Source: Talanta
Language: English
Subfield: Biomedical Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: hybrid
Estimated APC paid: $4,610
OpenAlex ID: W4409838707