Abstract: : The Shear walls are commonly used as a vertical structural element. They are used for resisting the lateral loads which are induced by the loads due to wind and earthquake. Besides shear walls also carry gravity loads. An attempt is made for seismic analysis of RCC building bare frame & with shear wall at corner position using STAAD Pro Connect Edition V22. A 11 storey building is taken under consideration. Two different Model of RCC building are used, one with no shear wall and other models with corner position of shear wall. Results will be obtained from analysis and plotted to compare and to have knowledge of behavior of RCC framed structures with shear walls using Equivalent lateral force static method Analysis which is subjected to earthquake load in zone V. The parameters like storey drift, lateral displacement, and base shear will be studied and suitable location of shear wall will be determined among these models. The whole analysis is done on STAAD Pro Connect Edition V22 software