Automated segmentation of thoracic aortic lumen and vessel wall on three-dimensional bright- and black-blood magnetic resonance imaging using nnU-Net
Year: 2025
Type: article
Abstract: Background Magnetic resonance angiography (MRA) is an important tool for aortic assessment in several cardiovascular diseases. Assessment of MRA images relies on manual segmentation; a time-intensive process that is subject to operator variability. We aimed to optimize and validate two deep-learning models for automatic segmentation of the aortic lumen and vessel wall in high-resolution ECG-triggered free-breathing respiratory motion-corrected 3D bright- and black-blood MRA images. Methods Manual segmentation, serving as the ground truth, was performed on 25 bright-blood and 15 black-blood 3D MRA image sets acquired with the iT2PrepIR-BOOST sequence (1.5T) in thoracic aortopathy patients. The training was performed with nnU-Net for bright-blood (lumen) and black-blood image sets (lumen and vessel wall). Training consisted of a 70:20:10% training: validation: testing split. Inference was run on datasets (single vendor) from different centres (UK, Spain, and Australia), sequences (iT2PrepIR-BOOST, T2 prepared CMRA, and TWIST MRA), acquired resolutions (from 0.9 mm 3 to 3 mm 3 ), and field strengths (0.55T, 1.5T, and 3T). Predictive measurements comprised Dice Similarity Coefficient (DSC), and Intersection over Union (IoU). Postprocessing (3D slicer) included centreline extraction, diameter measurement, and curved planar reformatting (CPR). Results The optimal configuration was the 3D U-Net. Bright blood segmentation at 1.5T on iT2PrepIR-BOOST datasets (1.3 and 1.8 mm 3 ) and 3D CMRA datasets (0.9 mm 3 ) resulted in DSC ≥ 0.96 and IoU ≥ 0.92. For bright-blood segmentation on 3D CMRA at 0.55T, the nnUNet achieved DSC and IoU scores of 0.93 and 0.88 at 1.5 mm³, and 0.68 and 0.52 at 3.0 mm³, respectively. DSC and IoU scores of 0.89 and 0.82 were obtained for CMRA image sets (1 mm 3 ) at 1.5T (Barcelona dataset). DSC and IoU score of the BRnnUNet model were 0.90 and 0.82 respectively for the contrast-enhanced dataset (TWIST MRA). Lumen segmentation on black blood 1.5T iT2PrepIR-BOOST image sets achieved DSC ≥ 0.95 and IoU ≥ 0.90, and vessel wall segmentation resulted in DSC ≥ 0.80 and IoU ≥ 0.67. Automated centreline tracking, diameter measurement and CPR were successfully implemented in all subjects. Conclusion Automated aortic lumen and wall segmentation on 3D bright- and black-blood image sets demonstrated excellent agreement with ground truth. This technique demonstrates a fast and comprehensive assessment of aortic morphology with great potential for future clinical application in various cardiovascular diseases.
Institutions: King's College London, Maastricht University Medical Centre, Maastricht University, The Heart Research Institute, St Vincent's Hospital Sydney, Pontificia Universidad Católica de Chile, Chelsea and Westminster Hospital NHS Foundation Trust, Chelsea and Westminster Hospital, Victor Chang Cardiac Research Institute, Universitat Autònoma de Barcelona, Instituto de Salud Carlos III, Vall d'Hebron Institut de Recerca, Vall d'Hebron Hospital Universitari, Technical University of Munich
Language: English
Subfield: Computer Vision and Pattern Recognition
Field: Computer Science
Domain: Physical Sciences
Open Access status: gold
Estimated APC paid: $3,000
Funders: Institute for Advanced Study, Institut Català de Nanociència i Nanotecnologia, National Institute for Health and Care Research, British Heart Foundation, Royal Australasian College of Physicians, Technische Universität München, European Association of Cardiovascular Imaging, Centro Singular de Investigación de Galicia, Agencia Nacional de Investigación y Desarrollo, Engineering and Physical Sciences Research Council, Centre For Medical Engineering, King’s College London, Fondo Nacional de Desarrollo Científico y Tecnológico
Awards: G1190480411, FREE-RUNNING CARDIAC MRF AT 0.55T WITH SELF-SUPERVISED PHYSICS INFORMED DEEP LEARNING, G4476985772, G49213722, Detection of high-risk plaque with tropoelastin- specific and multicontrast coronary MRI (renewal), G5727464813, CENTER OF INTERVENTIONAL MEDICINE FOR PRECISION AND ADVANCED CELLULAR THERAPY (IMPACT), MILLENNIUM INSTITUTE FOR INTELLIGENT HEALTHCARE ENGINEERING, G597271902, G74904685, G8025796880, TOWARDS A 20 MIN CARDIAC MRI EXAM AT 0.55T: SIMPLE, EFFICIENT AND AFFORDABLE, Contrast-free Deep Myocardial Tissue Characterization with Cardiac MR Fingerprinting
OpenAlex ID: W4411219873
