Year: 2025
Type: article
Study design: Case Report
Abstract: The LINX Reflux Management System is a surgical procedure often done in conjunction with a hiatal hernia repair to manage gastroesophageal reflux disease (GERD). The surgical procedure was developed as an alternative to Nissen fundoplication and is postulated to last indefinitely. Common complications of the LINX device surgery are dysphagia, postoperative pain, and gastric bleeding. One side effect that has not been reported as a complication of the surgery is dumping syndrome. We report on a possible case of dumping syndrome post hiatal hernia repair with LINX magnetic sphincter augmentation diagnosed clinically and confirmed with glucose tolerance tests.
Source: Cureus
DOI: 10.7759/cureus.85893
Authors: Sandon Stokes, Harrison Torgerson, Kenyon Wilson, Mark Twardowski, David Lundy
Institution: Rocky Vista University
Language: English
Subfield: Gastroenterology
Field: Medicine
Domain: Health Sciences
Open Access status: diamond
OpenAlex ID: W4411288476
