Response Prediction and Performance Evaluation Based on Equivalent Linearization of High-rise Building With Hysteretic Dampers and Viscous Dampers
Year: 2025
Type: article
Abstract: In a high-rise building with a large bending deformation, the damping performance of middle to upper dampers may be deteriorated. To improve the deterioration of damping performance, a “combination-system” (High-rise building with hysteretic dampers and viscous dampers) is proposed. However, there is very little research on a response prediction method for “combination-system”. This paper presents a response prediction method and performance evaluation for “combination-system”. Accuracy of this prediction method is validated by comparing the predicted values with the time history analysis results. The performance curve is derived through the calculation process of the prediction method.
DOI: 10.3130/aijt.31.675
Authors: Kohei SOETA, Daiki SATO
Institutions: KUME Sekkei (Japan), Institute of Science Tokyo
Language: English
Subfield: Civil and Structural Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: diamond
OpenAlex ID: W4411443758