Year: 2025
Type: article
Abstract: The article discusses the causes of excessive noise and vibrations of a live steam pipeline in a power unit. A scanning laser vibrometer was used to measure the vibrations of the live steam pipeline for two power units. Additionally, the sound (noise) level of the live steam pipeline was measured with an acoustic camera. A discrete model of the pipeline was created, and FEM modal analysis was performed. Based on experimental tests and numerical simulations, the sources of noise were identified. The final conclusions propose methods of eliminating the harmful noise.
Source: Applied Sciences
DOI: 10.3390/app15126925
Institution: Wrocław University of Science and Technology
Language: English
Subfield: Automotive Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: gold
Estimated APC paid: $2,896
OpenAlex ID: W4411453057