Work

Comparison of Modular Neck Stem and Nonmodular Neck Stem in Primary Total Hip Arthroplasty: Findings of a Meta-Analysis

Year: 2025
Type: review
Abstract: Modular neck stem in total hip arthroplasty (THA) can offer variable option to reconstruct hip anatomy. However, concerns have been raised about the higher risk of revision of modular neck stem due to corrosion recently. We conducted this meta-analysis to supply a quantitative evaluation regarding this issue.We systematically searched PubMed, the Cochrane Library, EMBASE, Web of Science, Scopus, EBSCO from inception to January 2021. The trials comparing the survivorship and complications between modular-neck THA and nonmodular-neck THA were involved in the analysis.6 studies with 820523 participants were included. The outcomes of meta-analysis revealed that there were no significant differences between modular neck stem and nonmodular neck stem in revision rate (RR, 1.43; 95% CI, 0.99 to 2.04; P<0.00001), dislocation rate (RR, 1.38; 95% CI, 0.3 to 2.36; P<0.0001) and infection rate (RR, 1.12; 95% CI, 0.94 to 1.34; P=0.59).The utility of modular neck stem in THA offers similar survivorship compared to nonmodular neck stem. Current study demonstrated that utilization of modular neck stem is a reasonable choice in primary THA.
Author: <p>Gaohan Cai, Tengfeng Zhuang, Wenrui Wu, Zhengang Zha, Guorong She, Ning Liu</p>
Language: English
Subfield: Surgery
Field: Medicine
Open Access status: bronze
OpenAlex ID: W4411897939
FWCI:
Cites:
Cited by:
Related to: 10