Work

The temperature distribution in the ground on the two types of pipes of underground heating network

Year: 2025
Type: article
Abstract: District heating systems commonly utilize pre-insulated pipes arranged in either a parallel or TwinPipe configuration. This study compares the temperature distribution in the ground, as determined by a numerical 3D model, with experimental meas-urements conducted on a dedicated test setup. The analysis includes several district heating pipe variants (DN40, DN50 and DN65), and their counterparts in a single parallel pre-insulated system. The results obtained from laboratory experiments and numerical simulations show strong agreement, confirming the reliability of the proposed approach. The novelty of this work lies in the integration of experimental data and numerical simulations to improve the accuracy of heat loss estimations. The relative error between the computational and experimental models remains below 10%, ensuring high precision in the findings. The presented results provide valuable design insights for optimizing insulation thickness and pipe layout configurations in district heating networks. These findings contribute to the development of more efficient and sustainable thermal energy dis-tribution systems.
Language: English
Open Access status: diamond
OpenAlex ID: W4412373335
FWCI:
Cites:
Cited by:
Related to: 10