Work

Noninvasive Intracranial Pressure Prediction Using a Multimodal Ultrasound-Based Hemispheric Modeling Strategy: A Prospective Dual-Center Study

Year: 2025
Type: article
Study design: Observational Study
Abstract: Background Accurate intracranial pressure (ICP) surveillance is a cornerstone of neurocritical care management, yet invasive monitoring still depends on neurosurgical expertise, specialized hardware, and continuous bedside resources—factors that restrict universal use even though insertion-related complications are relatively uncommon. Contemporary noninvasive ultrasound methods have limited predictive accuracy and seldom incorporate affected side information. We therefore preliminarily validated a multimodal, ultrasound-based hemispheric modeling approach that blends hemodynamic and structural indexes while emphasizing affected side specificity to enhance ICP prediction. Methods In this prospective, dual-center study, 41 neurosurgical patients provided 216 paired ultrasound and invasive ICP measurements. Affected side and contralateral ultrasound parameters including pulsatility index, resistance index, optic nerve sheath diameter (ONSD), optic disk height, and ONSD-to-eyeball diameter ratio were analyzed. Linear mixed-effects models (LMMs) predicted continuous ICP, whereas generalized LMMs classified elevated ICP (≥ 20 mm Hg). Results Affected side parameters showed consistently stronger ICP correlations than unaffected side parameters. An affected side five-parameter LMM (pulsatility index, resistance index, ONSD, ONSD-to-eyeball diameter ratio, and optic disk height) provided superior continuous ICP prediction (coefficient of determination [ R 2 ] = 0.618, root mean square error = 0.424), significantly outperforming contralateral models ( R 2 = 0.338, root mean square error = 0.558). For binary classification, affected side ONSD demonstrated excellent accuracy (area under the receiver operating characteristic curve = 0.927, sensitivity = 91.4%, specificity = 79.5%), whereas the optimal affected side seven-parameter generalized LMM reached an area under the receiver operating characteristic curve of 0.829 (sensitivity = 80.8%, specificity = 75.8%). Conclusions This study demonstrated the feasibility and potential advantages of a novel hemispheric (side-specific) modeling strategy for noninvasive ICP assessment. The multiparameter model constructed using affected side ultrasound parameters exhibited promising predictive accuracy, providing a potentially valuable and innovative noninvasive approach for ICP monitoring in neurocritical care patients that may serve as an adjunct when invasive monitoring is unavailable, although further validation is warranted.
Language: English
Subfield: Neurology
Field: Medicine
Open Access status: hybrid
Estimated APC paid: $4,690
OpenAlex ID: W4413108339
FWCI: 1.691
Cites: 34
Cited by: 3
Related to: 10