Work

Direct thrust control of PMLSM based on mode-free adaptive control

Year: 2025
Type: conference-paper
Abstract: The permanent magnet linear synchronous motor (PMLSM) is susceptible to parameter time-varying, and the direct thrust force control (DTFC) system of PMLSM, and the thrust ripple and flux ripple are large. In order to improve the control accuracy of the DTFC system, this thesis combines the thrust and flux linkage hysteresis controllers in the DTFC system into a control loop, and uses the compact form dynamic linearization-model free adaptive control (CFDL-MFAC) algorithm based on tight format dynamic linearization to optimize the combined control loop. The results showed that it does not greatly reduce the thrust fluctuation and flux ripple.
Authors: Chunhan Wang, Xu Dong, Xiuping Wang, Hanyu Li
Language: English
Open Access status: diamond
OpenAlex ID: W4413154057
FWCI:
Cites: 3
Cited by:
Related to: 10