Abstract: This study investigates the limitations of existing gas quality measurement systems under hydrogen blending in natural gas transmission pipelines. Experimental analysis with 2-20% hydrogen-enriched gases revealed significant measurement errors in current analyzers, due to low hydrogen sensitivity and poor H 2 -N 2 separation. Among three improvement strategies, full replacement with analyzers suitable for hydrogen blending was found most effective in terms of cost, accuracy, and stability. The study also reviews recent developments and certification cases of commercial analyzers, and proposes follow-up tasks including performance validation, uncertainty evaluation, system optimization to ensure reliable gas quality measurement under hydrogen blending.