Comunicación interventricular como complicación infrecuente luego de un reemplazo valvular aórtico mecánico
Year: 2024
Type: article
Study design: Case Report
Abstract: Although there is a long list of possible complications following aortic valve replacement, interventricular septal lesions are exceptional. A case is presented of a 24-year-old patient with arterial hypertension secondary to aortic coarctation, bicuspid aortic valve with mild regurgitation, and atrial septal defect, who underwent closure of the shunt with an Amplatzer device and aortic stent in 2018. In 2023, the patient developed severe aortic regurgitation and underwent mechanical valve replacement. The surgery was complicated by ventricular fibrillation and postoperative bleeding. During follow-up, a double murmur was auscultated, one corresponding to the prosthesis and another holosystolic, harsh at the Erb's point. An echocardiogram revealed perimembranous ventricular septal defect.
DOI: 10.63600/s4fgk644
Language: English
Subfield: Cardiology and Cardiovascular Medicine
Field: Medicine
Domain: Health Sciences
Open Access status: diamond
OpenAlex ID: W4414178725
FWCI:
Cites:
Cited by:
Related to: