Intelligent laparoscopic grasper with hybrid neural networks for real-time vascular detection in minimally invasive surgery
Year: 2025
Type: article
Abstract: SignificanceWe address the challenge of inadequate force feedback in laparoscopic surgery, which increases the risk of vessel injury. By integrating fiber Bragg grating (FBG) sensors with a laparoscopic grasper and employing a convolutional neural network combined with long short-term memory (CNN-LSTM) algorithm, this approach enables real-time, accurate vessel identification, potentially reducing surgical complications.AimLaparoscopic surgery is often hindered by inadequate force feedback, especially in complex scenarios involving tumor invasion and pelvic-abdominal adhesion, leading to challenges in locating blood vessels and an increased risk of vessel injury. Thus, it is desirable to develop a laparoscopic system capable of distinguishing the location and type of the vessels during surgery, which requires a compact and highly sensitive sensor integrated with a laparoscopic grasper.ApproachWe present an innovative laparoscopic grasper integrated with FBG force sensors for real-time force feedback, employing silicone and porcine vessel models to simulate varying depths and tissue coverage. The device successfully captured specific vessel signals, which were processed through a CNN-LSTM algorithm, enabling real-time vessel identification in minimally invasive surgery (MIS).ResultsThe intelligent laparoscopic grasper successfully obtained distinct vessel signals under varying conditions. As a result, the mean vessel gripping force for porcine vessel model III was 0.059 N under fatty tissue and 0.032 N under muscle tissue (p<0.001). The CNN-LSTM algorithm achieved a precision of 97.06% in vessel identification across different tissue coverages.ConclusionsThe FBG sensor-integrated laparoscopic grasper, assisted by the processing of the CNN-LSTM algorithm, demonstrated the ability to identify vessels ex vivo across different models. This technology holds potential for real-time and accurate vessel identification during MIS, which could significantly reduce the occurrence of unnecessary vessel injuries.
Source: Journal of Biomedical Optics
Authors: Pingping Wang, Yuting Huang, Chang Liu, Ziying Huang, Yuxin Huang, Yuan Wu, Zhengying Wang, Kaichao Chen, Zhengyong Liu, Dongxian Peng
Language: English
Subfield: Biomedical Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: gold
Estimated APC paid: $1,675
OpenAlex ID: W4414226461
FWCI:
Cites:
Cited by:
Related to: