Abstract: BACKGROUND: Pediatric interventional cardiology (IC) is an important diagnostic and therapeutic approach for addressing congenital heart disease (CHD) in children. However, the associated ionizing radiation raises long-term health concerns, emphasizing the need for dose optimization. PURPOSE: To establish multicenter diagnostic reference levels (DRLs) for pediatric IC procedures within the French COCCINELLE cohort as part of the HARMONIC European project, providing data to optimize radiation exposure. METHODS: A retrospective analysis of radiation dose metrics was conducted on pediatric IC procedures performed across seven hospitals from 2018 to 2020. Data were stratified by five weight groups (<5, 5- < 15, 15- < 30, 30- < 50, 50- < 80 kg) and seven IC procedure categories. Median and 75th quantile values for dose-area product (DAP), DAP normalized to body-weight (DAP/BW) and fluoroscopy time (FT) were calculated to define typical values and DRLs, respectively. The DRL-weight curve approach was also used to determine the 50th quantile curve for each IC procedure category. RESULTS: A total of 1815 pediatric IC procedures were analyzed, comprising 534 diagnostic and 1281 therapeutic procedures. Significant variations in DAP were observed across different procedure types and weight groups, while fluoroscopy time showed no significant variation. Typical-DRL values (median-75th percentile values) of DAP (Gy·cm²) ranged from 1.9-3.9 to 4.8-5.8 for coronarography, from 0.7-1.3 to 9.2-15.6 for angiography, from 0.3-0.6 to 0.8-1.5 for pulmonary valve dilatation, from 2.8-3.7 to 11.6-14.6 for pulmonary artery dilatation and stenting, from 0.6-1.3 to 2.8-6.0 for atrial septal defect closure and from 0.1-0.4 to 3.1-5.4 for patent ductus arteriosus closure in function of weight groups and 0.2-0.3 for Rashkind in patients <5 kg. CONCLUSION: This study provides the first multicenter DRLs for pediatric IC procedures in France, offering valuable benchmarks for dose optimization. These findings lay a strong foundation for future national and international guidelines in pediatric IC care.
Source: PLoS ONE
Authors: Bouchra Habib Geryes, Soline Bondet De La Bernardie, Sébastien Hascoet, Charlotte Geant, Claire Dauphin, Stéphanie Douchin, Julia Rousseau, François Godart, Valérie Pontvianne, Caroline Ovaert Reggio, Bruno Lefort, Aurore Danvin, Sylvaine Caer-Lorho, Marie-Odile Bernier, Damien Bonnet, Estelle Rage
Institutions: Hôpital Necker-Enfants Malades, Université Paris Cité, Assistance Publique – Hôpitaux de Paris, Autorité de sûreté nucléaire et de radioprotection, Hôpital Marie Lannelongue, Centre Hospitalier Universitaire de Clermont-Ferrand, Centre Hospitalier Universitaire de Grenoble, Hôpital Couple Enfant, Centre Hospitalier Universitaire de Lille, Inserm, Aix-Marseille Université, Assistance Publique Hôpitaux de Marseille, Hôpital de la Timone, Centre de Génétique Médicale de Marseille, Centre Hospitalier Universitaire de Tours
Language: English
Topic: Radiation Dose and Imaging
Subfield: Radiology, Nuclear Medicine and Imaging
Field: Medicine
Domain: Health Sciences
Open Access status: gold
Estimated APC paid: $2,382
OpenAlex ID: W4414270246