Late Thrombosis of First-Generation Bioresorbable Scaffold Site Treated With Novel Resorbable Magnesium Scaffold
Year: 2025
Type: article
Study design: Case Report
Abstract: BACKGROUND: To the best of our knowledge, this is the first reported experience of a patient with late thrombosis of previous Absorb (Abbott Vascular) bioresorbable scaffold (BRS) implantation site, treated with second-generation Magmaris (Biotronik) resorbable magnesium scaffold (RMS). CASE SUMMARY: A 55-year-old man with a previously implanted Absorb BRS stent presented with a non-ST-elevation myocardial infarction. Coronary angiography showed thrombotic lesion at the BRS stent site. After intravascular optical coherence tomography (OCT) imaging, a decision was made to implant a second-generation RMS stent. OCT follow-up was performed, with excellent long-term results. DISCUSSION: Randomized controlled trials have connected early BRS implantation to a higher rate of stent thrombosis. In recent years, the newer generation RMS has confirmed a good safety profile and long-term patency. The idea behind this treatment was to assess the novel RMS technology with serial OCT imaging. TAKE-HOME MESSAGES: This case adds new options for the treatment of coronary arteries with novel RMS technology. Intravascular imaging with OCT is essential for optimized treatment and follow-up.
Source: JACC Case Reports
Authors: Jorgo Kostov, Biljana Zafirovska, Sasko Kedev
Institution: Ss. Cyril and Methodius University in Skopje
Language: English
Subfield: Surgery
Field: Medicine
Domain: Health Sciences
Open Access status: gold
Estimated APC paid: $850
OpenAlex ID: W4414536931