Descemet’s Membrane Detachment Following Inadvertent Intrastromal Injection of an Ophthalmic Viscoelastic Device
Year: 2025
Type: article
Study design: Case Report
Abstract: Hypotony is a well-documented postoperative complication of glaucoma filtration surgery. Management may include the injection of an ophthalmic viscoelastic device (OVD) into the anterior chamber. This case report describes a 45-year-old woman with juvenile-onset open-angle glaucoma who developed clinical hypotony after trabeculectomy surgery augmented with mitomycin-C. An intracameral injection of Healon5® (Johnson & Johnson Vision, USA) was attempted to restore physiological intraocular pressure (IOP); however, Healon5® was inadvertently introduced into the corneal stroma, causing a localised Descemet's membrane detachment (DMD). Following non-resolution with observation and attempted surgical evacuation, an intracameral air tamponade successfully addressed the DMD. An intracameral air tamponade may provide a quicker alternative to prolonged observation, particularly for highly cohesive OVDs such as Healon5®.
Source: Cureus
DOI: 10.7759/cureus.93383
Institution: The Royal Wolverhampton NHS Trust
Language: English
Subfield: Radiology, Nuclear Medicine and Imaging
Field: Medicine
Domain: Health Sciences
Open Access status: diamond
OpenAlex ID: W4414584656