Work

Research on Frequency Characteristic Fitting of LLC Switching-Mode Power Supply Under All Operating Conditions Based on FT-WOA-MLP

Year: 2025
Type: article
Abstract: The frequency characteristics of the switching-mode power supply (SMPS) control loop under all operating conditions are crucial for performance evaluation and defect detection. Traditional methods, relyingon experiments under preset conditions, struggle to achieve comprehensive evaluation. This study proposes a frequency characteristic fitting method for all operating conditions based on FT-WOA-MLP. A discrete-point dataset covering all conditions of an LLC SMPS was obtained using the small-signal perturbation method, including input voltage, output current, injection frequency, and corresponding amplitude- and phase-frequency characteristics. The multilayer perceptron (MLP) model was trained on the training set covering all operating conditions, with the whale optimization algorithm (WOA) used to optimize the learning rate, and fine tuning (FT) applied to further enhance accuracy. Independent test set validation showed that, for amplitude-frequency characteristics, the mean absolute error (MAE) was 2.0995, the mean absolute percentage error (MAPE) was 0.0974, the root mean square error (RMSE) was 4.0474, and the coefficient of determination (R2) reached 0.92; for phase-frequency characteristics, the MAE was 3.502, the MAPE was 0.0956, the RMSE was 10.5192, and the R2 reached 0.94. The method accurately fits frequency characteristics under all conditions, supporting defect identification and performance optimization.
Language: English
Open Access status: gold
Estimated APC paid: $2,172
OpenAlex ID: W4414593265
FWCI:
Cites: 32
Cited by:
Related to: