Study on Excitation Force Caused by Vertical Motion of Audience Based on Continuously Measured Data of Live Hall Floor Vibration
Year: 2025
Type: article
Abstract: The vibration isolation floor using an inertial mass device developed by the authors is a floating floor structure with a clear load-deformation relationship, which enables an accurate evaluation of the excitation force of the audience’s vertical motion. Based on data obtained by measuring the vibration of a live hall floor for one year, we analyzed the excitation force of a hall floor for 1,000 people. By adjusting the inertia mass ratio considering the frequency dependence of the excitation force, the vibration isolation floor with an inertia mass device can significantly reduce the reaction force compared to a conventional floating floor.
DOI: 10.3130/aijs.90.1177
Authors: Naoto YOSHIDA, Sachie KOTSUKI, Yuta TOMIYOSHI, Takashi AOKI
Institution: Shimizu (Japan)
Language: English
Subfield: Civil and Structural Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: bronze
OpenAlex ID: W4414639476
FWCI:
Cites:
Cited by:
Related to: