Impact of embedded $$^{163}$$Ho on the performance of the transition-edge sensor microcalorimeters of the HOLMES experiment
Year: 2025
Type: article
Abstract: We present a detailed investigation of the performance of transition-edge sensor (TES) microcalorimeters with $$^{163}$$ 163 Ho atoms embedded by ion implantation, as part of the HOLMES experiment aimed at neutrino mass determination. The inclusion of $$^{163}$$ 163 Ho atoms introduces an excess heat capacity due to a pronounced Schottky anomaly, which can affect the detector’s energy resolution, signal height, and response time. We fabricated TES arrays with varying levels of $$^{163}$$ 163 Ho activity and characterized their performance in terms of energy resolution, decay time constants, and heat capacity. The intrinsic energy resolution was found to degrade with increasing $$^{163}$$ 163 Ho activity, consistent with the expected scaling of heat capacity. From the analysis, we determined the specific heat capacity of $$^{163}$$ 163 Ho to be $$(2.9 \pm 0.4 \mathrm {(stat)} \pm 0.7 \mathrm {(sys)})$$ ( 2.9 ± 0.4 ( stat ) ± 0.7 ( sys ) ) J/K/mol at $$(94 \pm 1)$$ ( 94 ± 1 ) mK, close to the literature values for metallic holmium. No additional long decay time constants correlated with $$^{163}$$ 163 Ho activity were observed, indicating that the excess heat capacity does not introduce weakly coupled thermodynamic systems. These results suggest that our present TES microcalorimeters can tolerate $$^{163}$$ 163 Ho activities up to approximately 5 Bq, with only about a factor of three degradation in performance compared to detectors without $$^{163}$$ 163 Ho. For higher activities, reducing the TES transition temperature is necessary to maintain or improve the energy resolution. These findings provide critical insights for optimizing TES microcalorimeters for future neutrino mass experiments and other applications requiring embedded radioactive sources. The study also highlights the robustness of TES technology in handling limited amounts of implanted radionuclides while maintaining high-resolution performance.
Source: The European Physical Journal C
Authors: Douglas Bennett, Matteo Borghesi, Pietro Campana, Rodolfo Carobene, Giancarlo Ceruti, Matteo De Gerone, Marco Faverzani, Lorenzo Ferrari Barusso, Elena Ferri, Joseph Fowler, Sara Gamba, Flavio Gatti, Andrea Giachero, Marco Gobbo, Danilo Labranca, Roberto Moretti, Angelo Nucciotti, Luca Origo, Stefano Ragazzi, Dan Schmidt, Daniel Swetz, Joel Ullom
Institutions: National Institute of Standards and Technology, Istituto Nazionale di Fisica Nucleare, Istituto Nazionale di Fisica Nucleare, Sezione di Milano, Istituto Nazionale di Fisica Nucleare, Sezione di Milano Bicocca, University of Milano-Bicocca, Istituto Nazionale di Fisica Nucleare, Sezione di Genova, University of Genoa, University of Colorado Boulder
Language: English
Subfield: Astronomy and Astrophysics
Field: Physics and Astronomy
Domain: Physical Sciences
Open Access status: diamond
OpenAlex ID: W4414650884
