Work

Accuracy of a novel ultrasound biomicroscope for measuring corneal epithelial thickness and agreement with an SD-OCT based device

Year: 2025
Type: article
Study design: Observational Study
Abstract: • Accurate corneal epithelial thickness (ET) measurement is vital for diagnosing ocular diseases and monitoring post-surgical changes. Spectral-domain optical coherence tomography (SD-OCT) is widely used for ET measurement, but its accuracy can be compromised by tear film effects. • VHF-UBM is an alternative, but its repeatability and agreement with SD-OCT in various conditions are not fully established. • This study evaluates the repeatability and reproducibility of the Insight 100 VHF-UBM in both healthy and post-T-PRK eyes, providing new data on its precision. It compares Insight 100 with SD-OCT, highlighting their agreement and interchangeability, particularly in central corneal epithelial thickness measurements. To assess the accuracy of corneal epithelial thickness (ET) measurements in healthy and post transepithelial photorefractive keratectomy (post-T-PRK) eyes using a novel ultrasound biomicroscope (Insight 100, ArcScan, Colorado, USA) and to compare the agreement with the measurements provided by a spectral-domain optical coherence tomographer (RTVue-XR, Optovue, Fremont, CA). In total, 32 healthy and 38 post-T-PRK eyes were included. Three consecutive measurements of right eye were acquired with the Insight 100 VHF-UBM and RTVue-XR SD-OCT. Accuracy was analyzed using intraclass correlation coefficient (ICC), test-retest repeatability (TRT), within-subject coefficient of variation (CoV), and within-subject standard deviation (S w ). Agreement was assessed by Bland-Altman analysis and paired t-tests. The precision of the normal eyes were higher than post-T-PRK eyes. Central epithelial thickness (CET) had the best repeatability and reproducibility, CoV was 0.5%∼1.71%. The S w and TRT was 0.35µm and 0.79µm in normal eyes, 1.02µm and 1.92µm in post-T-PRK eyes. ET superior-6mm has poor repeatability in normal eyes. However, post-T-PRK eyes have the worst repeatability at ET inferior-3mm and ET temporal-3mm . Agreement of CET was excellent in both groups. The widest 95% LoA range appeared at ET superior-6mm of normal and post-T-PRK eyes, with 0.72∼8.74µm and -9.51∼7.32µm, respectively. The Insight 100 provides good repeatability and reproducibility for ET measurements in normal and post-T-PRK eyes. CET can be used interchangeably between Insight 100 and RTVue-XR, however, it is not recommended for other positions.
Language: English
Field: Medicine
Open Access status: gold
Estimated APC paid: $2,610
OpenAlex ID: W4414997297
FWCI: 0.545
Cites: 34
Cited by: 1
Related to: