Work

Development and Validation of a Sensitive Lc-ms/ms Analytical Method for Quantifying Axitinib With Axitinib D3 as an Internal Standard

Year: 2025
Type: article
Abstract: Objective: An efficient, highly sensitive, and robust LC-MS/MS method has been optimized, validated for accurately measuring Axitinib concentrations in human plasma, utilizing Axitinib D3 as an internal standard. Methods: A liquid–liquid extraction approach was utilized to isolate both the analyte and the internal standard from the plasma matrix. An Eclipse Phenyl column of 100 × 3.0 mm size with 5 µm particles operated using a mobile phase containing methanol mixed with 0.1% formic acid in 10 mM ammonium formate at a ratio of 60:40 (v/v) following the advanced bioanalytical framework for method establishment and validation. Results: The complete chromatographic run was accomplished in 4.0 minutes, with the analyte and internal standard eluting at approximately 1.89 minutes. The assay demonstrated a validated linear response across the concentration range of ~ 0.2 to 125 ng/mL. The developed method was thoroughly validated for key parameters including precision, accuracy, selectivity, matrix effects, and stability. All validation results met the predefined specifications, confirming method's reliability. Conclusion: The validated method for quantifying Axitinib in human plasma complies with regulatory guidelines set by the FDA and EMA, making it appropriate for pharmacokinetic studies in human subjects.
Authors: KUPPIRALA SANDEEP CHAKRAVARTHI, KANALA SOMASEKHAR REDDY
Language: English
Field: Chemistry
Open Access status: diamond
OpenAlex ID: W4415026885
FWCI:
Cites: 23
Cited by:
Related to: