Year: 2025
Type: article
Study design: Case Report
Abstract: Post-implantation infections of pacemakers or defibrillators represent a serious complication, impacting patient morbidity and mortality. We present a case involving a 75-year-old male with multiple comorbidities who developed pocket erosion of a previously implanted biventricular defibrillator, complicated by Staphylococcus haemolyticus infection. Following device extraction and targeted antibiotic therapy, an extravascular implantable cardioverter defibrillator (EV-ICD; Aurora EV-ICD) was implanted. The procedure was successfully performed, with a 2-month follow-up showing no signs of infection or device displacement. EV-ICD appears to be a safe and effective alternative for high-risk patients, minimizing complications associated with vascular access and endocardial lead implantation.
DOI: 10.1111/pace.70045
Authors: Giuseppe Coppola, Salvatore Torre, Leonardo D'Amico, Amedeo Calè, Alfredo R. Galassi, Egle Corrado
Language: English
Subfield: Cardiology and Cardiovascular Medicine
Field: Medicine
Domain: Health Sciences
Open Access status: green
OpenAlex ID: W4415032349