Single-distance, phase-only frequency-domain NIRS for vascular oxygenation and tissue metabolism: a Monte Carlo simulation study
Year: 2025
Type: article
Abstract: SignificanceFrequency-domain near-infrared spectroscopy (FD-NIRS) currently enables absolute hemoglobin quantification but requires multidistance measurements of both amplitude attenuation and phase shifts. Notably, existing FD-NIRS approaches have not demonstrated reliable quantification of differential redox-state concentrations of cytochrome c oxidase (CCOredox), a critical metabolic marker.AimWe aimed to develop a novel optimization-based algorithm for single source-detector (S-D), phase-only FD-NIRS that achieves accurate quantifications of hemoglobin parameters (HbO and Hb) and CCOredox.ApproachOur computational framework implemented both forward modeling and inverse reconstruction. For the modeling, we first defined chromophore concentration sets (HbO, Hb, CCOredox), followed by calculations of wavelength-dependent optical properties for two- or eight-wavelength configurations. Next, time-domain photon propagation was generated via Monte Carlo (MC) simulations, and FD-NIRS parameters (modulation amplitude, phase) were extracted through Fourier analysis. In the inverse computation, nonlinear optimization with edge-barrier regularization was employed for the recovery of chromophore concentrations. Both the multiseparation method and the single S-D, phase-only algorithm were used to reconstruct chromophore concentrations.ResultsRespective performances evaluated for the two methods were compared through their concentration recovery accuracy. In either the two- or eight-wavelength configuration, our new algorithm outperformed the conventional method for the S-D separations up to 3 cm for all three chromophores. In particular, CCOredox estimation was improved markedly from a mean relative error of 34.1% with the conventional method to just 5.1% using our algorithm.ConclusionsThese results validate single-separation phase-only FD-NIRS as an accurate method for multichromophore quantification (including CCOredox), enabling simpler, cost-effective systems without compromising metabolic imaging capability. The approach achieves <10% error in hemoglobin quantification while eliminating traditional multidistance requirements.
Source: Journal of Biomedical Optics
Institution: The University of Texas at Arlington
Language: English
Subfield: Radiology, Nuclear Medicine and Imaging
Field: Medicine
Domain: Health Sciences
Open Access status: gold
Estimated APC paid: $1,675
OpenAlex ID: W4415263303
FWCI:
Cites:
Cited by:
Related to:
