Work

Ultra-low thickness bio-degradable polymer vs durable polymer everolimus eluting stents – A 24 months clinical follow-up study

Year: 2025
Type: article
Study design: Observational Study
Abstract: A multicenter observational study of 2059 PCI patients compared the ultrathin-strut BDP-EES (Eternia) with the DP-EES (Xience) over 24 months. Patients in the Eternia group were older with more chronic total occlusions. MACE rates were 3.7 % (Xience) vs 3.8 % (Eternia; p = 0.939), with no significant differences in mortality, TVR, or stent thrombosis. No definite or probable stent thrombosis was reported in either group, and possible thrombosis rates were low (0.3 % vs 0.4 %). These findings suggest that biodegradable and durable polymer platforms offer similar long-term performance. The Eternia stents demonstrated equivalent safety and efficacy to Xience stents at 24 months.
Authors: Upendra Kaul, Pushpendra Kumar Garg, Rohit Chopra, Rahul Gupta, Vivek Mathur
Language: English
Subfield: Surgery
Field: Medicine
Open Access status: gold
Estimated APC paid: $360
OpenAlex ID: W4415312298
FWCI: 0.869
Cites: 11
Cited by: 1
Related to: