Research on line pilot protection of dual-end weak-fed AC system based on membership degree discrimination of transient impedance model
Year: 2025
Type: article
Abstract: • The proposed method is not affected by the control strategy and and can quickly identify faults. • The proposed method has lower requirement for communication synchronization. • The proposed method is not affected by line parameters and does not require simulation setting. • The proposed scheme is not affected by the sampling rate, and can resist the interference of high resistance and noise. At the dual-end weak-fed AC system with a significant share of renewable energy integration, flexible DC technology is mostly used in the form of delivery. In such a system with weak feedback at both ends, the influence of the control strategy makes the fault characteristics change essentially. Therefore, it is very important to study the fast protection that is not affected by the control strategy. Among them, the single-ended protection cannot protect the full length of the line and requires high sampling rate. The pilot protection can identify the fault more reliably. However, the existing pilot protection methods have problems such as dependence on detailed system parameters, strict communication synchronization, and complex algorithms. Therefore, A pilot protection based on logical quantity transmission, which does not depend on a large number of parameters, is proposed. Firstly, it is theoretically analyzed that the transient characteristics between fault transient voltage (FTV) and fault transient current (FTC) satisfy the negative resistance-inductance series model when a positive fault occurs in a specific frequency band. When a reverse fault occurs, it satisfies the positive resistance model relationship. Secondly, the frequency characteristics of each impedance are analyzed and the generalized S transform is used to extract the specific frequency band of the signal. Then, the model error is introduced to measure the model membership degree (MMD). The fault direction is identified by the error difference between the two fault models. Finally, based on the above theory, a directional pilot protection that relies only on logic transmission is proposed. PSCAD / EMTDC simulation results show that the proposed method can correctly identify internal and external faults at a sampling rate of 10 kHz. It can withstand 300 Ω fault resistance and 20 dB noise. © 2017 Elsevier Inc. All rights reserved.
Authors: Dan Liu, Yifan Zhao, Yu Sun, Ping Xiong, Xiaoqian Zhu, Mengyao Liu, Junjie Hou, Yanfang Fan, Guobing Song
Institutions: State Grid Corporation of China (China), Xinjiang University
Language: English
Subfield: Control and Systems Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: gold
Estimated APC paid: $3,920
Awards: G2232452438, G231703751, G293910773
OpenAlex ID: W4415322204