Work

Cardiac tamponade due to internal jugular catheterization after lung resection: a rare but life-threatening complication (case report)

Year: 2025
Type: article
Study design: Case Report
Abstract: INTRODUCTION: Internal jugular venous catheterization is an invasive procedure, and there are life-threatening complications that require urgent intervention. In this study, we present a young patient who developed myocardial injury due to internal jugular catheterization. CASE: The patient underwent middle lobectomy for bronchiectasis. Right internal jugular venous catheterization was performed. In the fourth postoperative hour, resuscitation was initiated due to sudden hypotension, tachycardia, and altered consciousness. Bedside echocardiography, performed to evaluate the etiology of the acute presentation, revealed diffuse fluid accumulation in the pericardial cavity. Following fluid drainage, hemodynamic stability was achieved. DISCUSSION: Possible complications can be life-threatening, and rapid diagnosis along with prompt treatment may be life-saving.
Language: English
Field: Medicine
Open Access status: gold
Estimated APC paid: $3,190
OpenAlex ID: W4415420296
FWCI:
Cites: 11
Cited by:
Related to: