Work

Transcatheter Valve Replacement in Adults With Congenital Heart Disease—The Mayo Clinic Experience

Year: 2025
Type: article
Study design: Observational Study
Abstract: BACKGROUND: The current study aims to describe outcomes after transcatheter valve replacement in adults with congenital heart disease. METHODS: Retrospective study of adults with congenital heart disease who underwent transcatheter valve replacement and had a 1-year follow-up postintervention at Mayo Clinic (2010–2024). The study period was divided into early (2010–2014), mid (2015–2019), and late (2020–2024) eras. The primary outcome was valve reintervention. The secondary outcomes were all-cause mortality and temporal change in prosthetic valve gradient and clinical indices of disease severity. RESULTS: Overall, 341 patients (age 38±17 years; 175 [51%] men) received 346 prostheses (pulmonary [N=236, 68%], tricuspid [N=75, 22%], aortic [N=22, 8%], and mitral [N=7, 2%]). The prostheses were Sapien (N=181, 52%), Melody (N=142, 41%), and Harmony prostheses (N=23, 7%). The number of transcatheter valve implantations increased from the early era (N=75), mid era (N=109), to the late era (N=162). The 10-year incidence of valve reintervention was 35%, and was similar between Sapien versus Melody prosthesis (41% versus 33%; P =0.11). The 10-year incidence of all-cause mortality was 13%. There was a temporal increase in prosthetic valve Doppler mean gradient (baseline versus 10 years) for pulmonary (12±5 versus 28±11 mmHg; P <0.001), tricuspid (3±1 versus 8±3 mmHg; P <0.001), and aortic prosthesis (13±5 versus 26±12 mmHg; P <0.001). There was a temporal increase in predicted peak oxygen consumption (absolute ∆, 9% [95% CI, 4–13]; P =0.006) and a decrease in NT-proBNP (N-terminal pro-B-type natriuretic peptide) level (absolute ∆, −138 pg/mL [95% CI, −209 to −64]; P <0.001) at 1-year postintervention. CONCLUSIONS: There has been a temporal increase in the number of transcatheter valve implantations over time. Transcatheter valve replacement was associated with clinical improvement across multiple domains. However, there was a significant increase in prosthetic valve gradient within 10 years of follow-up, suggesting limited prosthesis longevity. There is a need for strategies to improve prosthetic valve longevity, which in turn may improve outcomes in this population.
Institution: Mayo Clinic
Language: English
Subfield: Epidemiology
Field: Medicine
Open Access status: hybrid
OpenAlex ID: W4415615079
FWCI: 1.246
Cites: 23
Cited by: 2
Related to: