Analyzing Cardiorespiratory Motion and Its Dosimetric Effect on Stereotactic Arrhythmia Radio-Ablation: A STOPSTORM.eu Consortium Study
Year: 2025
Type: article
Study design: Observational Study
Abstract: Purpose Stereotactic arrhythmia radio-ablation (STAR) is increasingly used to treat refractory ventricular tachycardia. The importance of cardiorespiratory motion during STAR is still poorly understood. We collected multicenter STOPSTORM.eu data to estimate cardiorespiratory motion and its dosimetric impact on STAR-deliveries. Methods and Materials Data were collected from 61 ventricular tachycardia patients. Treatments were performed in free-breathing (FB) with an internal-target volume (FB:ITV) (25 patients), in FB with respiratory beam tracking (FB:TR) (11 patients), using abdominal compression (AC) (10 patients), or in deep inspiration breath-hold (BH) (15 patients). Reference computed tomography images were registered to all breathing/cardiac phases, and the resulting deformation vector fields were used to extract motion for target structures and auto-contoured cardiorespiratory structures (CSs). Additionally, CS were auto-contoured on all breathing/cardiac phases to extract motion independently. Inverse deformation vector fields were used to accumulate motion-adjusted dose distributions. Dose differences were estimated using the conformity index: (V PTV25Gy ) 2 /(V PTV · V 25Gy ), for planning target volume, and maximum and mean dose differences for CS. Results The median 95th percentile planning target volume motion was comparable between patients, with 6.0 mm (FB), 5.6 mm (AC), and 4.9 mm (BH). The left ventricle had the highest median 95th percentile motion out of all CS, with 6.8 mm (FB), 5.5 mm (AC), and 5.9 mm (BH). Estimated motion values were comparable between deformable image registration and auto-contouring (FB, 2.9-7.6 vs 3.1-8.5 mm; AC, 2.4-15.1 vs 3.0-9.0 mm; BH, 1.0-7.3 vs 2.4-6.7 mm). Median conformity index was reduced in the accumulated dose compared to the planned dose by: FB:ITV (–7.2%), AC (–14.1%), BH (–4.3%), and FB:TR (–1.3%). Mean CS dose increased by up to 2 Gy, and maximum dose increased by up to 1.2 Gy (excluding outliers). The largest dose differences were found for small CS. Conclusions Motion and its dosimetric effect have similar magnitudes between treatment setups. Motion findings were consistent between deformable image registration and auto-contouring. Only tracking significantly limited the dosimetric impact of motion.
Authors: Luuk H.G. van der Pol, Stefano Mandija, Brian V. Balgobind, Slawomir Blamek, Judit Boda-Heggemann, Marian Christoph, Jakub Cvek, Javier de Areba Iglesias, Pavel Dvorak, Melanie Grehn, Colien Hazelaar, Gunther Klautke, Lukáš Knybel, Marcin Miszczyk, Mateusz Sajdok, Jorrit Visser, Bartłomiej Tomasik, Oliver Blanck, Martin F. Fast
Institutions: University Medical Center Utrecht, Amsterdam UMC Location University of Amsterdam, The Maria Sklodowska-Curie National Research Institute of Oncology, Heidelberg University, University Medical Centre Mannheim, Medizinische Fakultät Mannheim, Klinikum Chemnitz, University Hospital Ostrava, Hospital Clínico San Carlos, Instituto de Investigación Sanitaria del Hospital Clínico San Carlos, University Hospital Schleswig-Holstein, Maastricht University Medical Centre, Maastricht University, Maastro Clinic, Comprehensive Cancer Center Vienna, WSB University, Medical University of Vienna, Medical University of Silesia, Gdańsk Medical University
Language: English
Subfield: Radiation
Field: Physics and Astronomy
Domain: Physical Sciences
Open Access status: hybrid
Estimated APC paid: $4,130
Funders: Bristol-Myers Squibb, Varian Medical Systems, American Association of Physicists in Medicine, Elekta, Accuray, European Commission, European Association of Urology, Nederlandse Organisatie voor Wetenschappelijk Onderzoek, Astellas Pharma, Agentura Pro Zdravotnický Výzkum České Republiky, Horizon 2020 Framework Programme