A nonstandard custom-made device to treat a type IA endoleak 6 years after Nellix implantation
Year: 2025
Type: article
Study design: Case Report
Abstract: The Nellix graft has been withdrawn from the market for the early graft failures associated with sac enlargement and rupture. To manage this complication, open conversion has been described as the main solution. However, we report the case of an 85-year-old female patient admitted with a type IA endoleak on a Nellix graft, with 70-mm aneurysmal sac, and treated with a custom-made device manufactured by Cook, to fit the peculiar graft conformation and patient's anatomy. In this case, accurate prosthesis design and surgical planning were essential to complete the procedure with no intraoperative complications.
Institutions: Policlinico Umberto I, Sapienza University of Rome
Language: English
Subfield: Pulmonary and Respiratory Medicine
Field: Medicine
Domain: Health Sciences
Open Access status: gold
Estimated APC paid: $1,250
OpenAlex ID: W4415899603